What is the Proper Electrical Voltage
Electrical Voltage and Power Supply Requirements for KitchenAid Ice Makers
Providing the correct electrical voltage and circuit configuration is essential for normal refrigeration, circulation pump operation, and electronic control timing on KitchenAid under-counter and freestanding ice makers. If supplied with improper voltage or shared across an overloaded branch circuit, the ice maker can experience compressor stalling, incomplete harvest cycles, thin or malformed ice, and diminished cooling capacity.
Quick Answer: A KitchenAid ice maker requires a 115 Volt, 60 Hz, AC-only, 15-amp or 20-amp dedicated, properly grounded branch circuit. The power cord features a standard 3-prong grounding plug that must connect directly to a matching 3-prong grounded wall receptacle. Never plug the ice maker into an outlet controlled by a wall switch or pull chain, avoid using GFCI outlets due to nuisance tripping risks, and never use extension cords or 2-prong adapters.
Electrical Shock and Power Interruption Hazard: Plug directly into a grounded 3-prong outlet. Do not remove the ground prong, do not use an adapter, and do not use an extension cord. Connecting the ice maker to a GFCI (Ground Fault Circuit Interrupter) outlet can cause nuisance tripping, shutting off refrigeration and resulting in melted ice, standing water in the bin, and spoiled ice quality.
Quick Reference: Electrical Specifications
| Requirement | Factory Specification | Reason / Risk |
|---|---|---|
| Voltage | 115 Volts AC (60 Hz) | Under-voltage causes compressor overheating and hard starting |
| Circuit Rating | 15 Amp or 20 Amp | Accommodates compressor startup locked-rotor amperage (LRA) |
| Circuit Type | Dedicated line (serving only the ice maker) | Shared lines with high-draw appliances cause breaker trips and voltage drops |
| Outlet Type | 3-Prong grounding wall receptacle | Required by National Electrical Code (NEC) for physical ground safety |
| Switched Outlets | Not permitted (unswitched only) | Prevents accidental power loss from wall switches or pull chains |
| GFCI Protection | Not recommended | High-frequency compressor cycling causes nuisance breaker trips |
| Adapters / Extensions | Strictly prohibited | Undersized extension cords overheat and pose fire hazards |
Power Supply and Grounding Guidelines
- Dedicated Branch Circuit: Provide an isolated circuit serving only the ice maker. Sharing a circuit with other refrigeration units, microwaves, dishwashers, or garbage disposals can cause line voltage drops when other appliances cycle on, stalling the ice maker's compressor.
- Dedicated 3-Prong Receptacle: The unit comes equipped with a factory power supply cord terminating in a 3-prong grounding plug. It must be inserted into a matching, properly grounded 3-prong outlet installed in accordance with the National Electrical Code (NEC) and local municipal ordinances.
- Avoid Switched Outlets: The wall outlet must supply continuous, unswitched power. Never plug the ice maker into an outlet wired to a room wall switch, garbage disposal switch, or pull-chain fixture that can accidentally cut power to the machine.
- The Problem with GFCI Outlets: Connecting the ice maker to an outlet protected by a Ground Fault Circuit Interrupter (GFCI) or arc-fault interrupter often leads to nuisance tripping. Inductive electrical loads from the refrigeration compressor, recirculation pump motor, and hot gas bypass solenoid can trip sensitive GFCI breakers during startup, cutting cooling power unexpectedly.
Action: If nuisance tripping occurs, have a licensed electrician replace the GFCI receptacle with a dedicated standard grounded duplex outlet where local electrical codes permit.
For complete details on the electrical requirements for your Ice Make see the Owner's Manual or the Installation Instructions.
If you would like to download or view product literature for your appliance, please visit our Manuals and Literature page.