How to Install the Grid Harness
Installing the Cutter Grid Harness on a KitchenAid Under-Counter Ice Maker
The cutter grid in an under-counter ice maker uses low-voltage resistance wires arranged in a grid pattern to slice the frozen ice slab into uniform square cubes as it releases from the evaporator plate. The grid wiring harness delivers electrical current to heat these cutting wires and connects the grid assembly to the ice maker's main control board. A damaged, disconnected, or corroded grid harness will prevent the ice slab from cutting, causing a solid block of ice to sit indefinitely on top of the grid.
Electrical Shock Hazard: Always disconnect electrical power to the ice maker at the service panel or unplug the power cord before accessing internal electrical harnesses, control housings, or cutter grid components. Never touch electrical connections while the unit is energized.
Quick Reference: Grid Harness Diagnostic Checklist
| Check / Step | Expected Condition | Troubleshooting Action |
|---|---|---|
| Cutter Grid Power | 12V AC/DC across harness terminals during harvest | Test harness continuity with a multimeter if ice does not cut |
| Harness Connector | Clean, dry, and locked into socket | Inspect for corrosion, water intrusion, or bent pins |
| Wire Routing | Routed cleanly through moisture barriers/clips | Ensure wires do not touch sharp sheet metal or pinch behind the pan |
| Ice Cube Slab Behavior | Slab melts through grid within 5–10 minutes | If slab stays whole, check grid harness connection |
Step-by-Step Grid Harness Installation
- Disconnect Power and Water: Unplug the ice maker or flip the dedicated circuit breaker to OFF. Turn off the cold water supply valve.
- Remove Stored Ice and Clear the Bin: Scoop out and discard any ice remaining in the storage bin to access the upper internal housing.
- Remove the Cutter Grid Cover / Fascia: Locate the plastic front trim cover or splash shield protecting the cutter grid assembly (typically held by 1 or 2 Phillips-head screws or side snap tabs). Remove the fasteners and set the cover aside.
- Disconnect the Old Harness: Trace the wire harness from the side or rear of the cutter grid to the quick-disconnect terminal plug inside the internal liner or control housing. Depress the locking tab on the plastic Molex connector and pull the harness plugs apart.
- Mount and Align the New Grid Harness: Connect the terminal plug of the new grid harness into the matching receptacle on the ice maker wiring harness until the locking clip clicks firmly into place.
- Route Wires into Retaining Channels: Secure the harness lead into the molded wire clips and drip loops along the side of the liner. Make sure the harness is routed away from moving parts, the water distribution tube, and areas where condensation can drip directly into electrical contacts.
- Reinstall Covers and Restore Power: Reattach the front grid cover and tighten the retaining screws until snug. Plug the ice maker back in or restore power at the circuit breaker box, then open the water supply valve.
Please refer to your Owner's Manual or the Installation instructions for the complete details on installing the cutter grid harness and the ice level sensor harness.